ACP/ACCP/Honeycomb Sizes, Tolerances & Specs

Specifications and Features of VIVA ACP, ACCP, and Honeycomb Panels

Explore the comprehensive specifications of VIVA’s Aluminium Composite Panels (ACP), Advanced Composite Panels (ACCP), and Honeycomb Panels, designed to meet diverse construction and design needs. With varying thicknesses, widths, and fire safety ratings, these panels are engineered to deliver exceptional performance across a wide range of applications.

Our product range includes options such as LDPE, FR-B, FR-A2, ACCP-A2+, ZCP, and Honeycomb panels, each tailored to specific functional and aesthetic requirements. From fire ratings compliant with global standards to precise tolerances and extensive size options, VIVA panels offer unparalleled versatility and reliability for modern architectural projects.

Discover the technical details below to select the ideal panel for your next project, ensuring the perfect balance of durability, safety, and design innovation.

Sr No. Properties ACP Types
LDPE FR-B FR-A2 ACCP-A2+ ZCP Honeycomb
1 Thickness 2mm~8mm 3mm~8mm 3mm~6mm 3mm~6mm 3mm~8mm 10mm,12mm,20mm, 25mm
2 Width 900mm to 1670mm 900mm to 1670mm 900mm to 1670mm 900mm to 1670mm 900mm to 1670mm 1220
3 Length Upto 6000mm Upto 6000mm Upto 6000mm Upto 6000mm Upto 6000mm 2440,3050,3660,4000mm
4 Squarness Max 5mm Max 5mm Max 5mm Max 5mm Max 5mm Max 5mm
5 Fire Ratings Reaction to Fire
EN 13501-1
- B- s1,d0 A2- s1,d0 A2- s1,d0 - A1
6 Surface burning test
ASTM E 84
- FSI-15 & SDI-45 FSI-15 & SDI-115 - - FSI-0 & SDI-0
7 Ignition temperature of core
ASTM D1929
- - SIT- 509°C & FIT - 506°C - - -
8 Ignition temperature of Plastics
ASTM D1929
- SIT - 452°C & FIT - 429°C SIT - 475°C & FIT - 468°C - - -
9 Reaction to fire for Building
NFPA 285
- Passed Successfully Passed Successfully - - -